Simplex 4010 Installation Manual

Simplex 4010 Installation Manual Average ratng: 4,2/5 3885votes

font design software download free

Suzuki C50 Repair Manual. View and Download Simplex 4010 service manual online. 4010 Fire Alarms pdf manual download.

Tracker Marine Avalanche Manual. To ensure proper system operation, this product must be tested in accordance with NFPA72-1996, Chapter 7 after any programming operation or change in site- specific software. Reacceptance testing is required after any change, addition or deletion of system components, or after any modification, repair or adjustment to system hardware or wiring. All components, circuits, system operations, or software functions known to be affected by a change must be 100% tested. In addition, to ensure that other operations are not inadvertently affected, at least 10% of initiating devices that are not directly affected by the change, up to a maximum of 50 devices, must also be tested and proper system operation verified. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference.

Simplex 4010 Type: Addressable Fire Alarm Control Panel Manufacturing Date: 2010 Point Capacity: 250 SLC Protocol: Simplex IDNet Networking Protocol: Compatible with 4100U Network NAC's: 4 Power Supply: 4A Relays: 2 Programmable Coding Options: Continuous, Temporal, Fast March Time, Slow March Time (60BPM March Time available for SmartSync TrueAlert horns) Synchronization Support: Simplex SmartSync Built-In Communicator: Yes Programming: Front-Panel or RS-232 About this panel: The 4010 was introduced in 1998 and remains Simplex's most popular fire alarm panel. This is because it can cover just about any small to mid-size application and can be installed and wired by a contractor prior to being programmed by a Simplex tech. From a design perspective, it's probably my favorite. The build quality of the hardware is surperior to most competitors and the software is very well thought out. It's a nice system for collectors since it's easy to program and the passcodes can always be reset using a simple key combination (for liability reasons, contact me if you're a collector and would like to know how). The 4010 can become part of a 4100ES network with the addition of a card and can also support addressable TrueAlerts when connected to a TrueAlert IDNet controller. Similar competitor panels include the Fire-Lite MS-9200UDLS, Gamewell-FCI 7100, and Siemens FireSeeker.

Fire Alarm Panels: Panels I no longer have: Want more information on this panel? Chances are you can find it in the database. This area of the site is regularly stocked with vintage catalogs, rare manuals, and software, all for free! I believe in open and uncomplicated access to information.